Content :
ZW series self-priming sewage pumps are with self priming and sewage discharge. It means the pumps can not only be self priming as the same as ZX series self priming pump for clean water without foot valve and pouring water but also suck and discharge the large grain and long fiber and sediment and impurity in the waste water. And the performance is very steady. It is very convenient to operate and move and install and maintain.
1. Environment temperature is not higher than 45 degree celsius. Liquids temperatre is not higher than 120 degree celsius
2. Liquid PH: Cast iron pump for PH6- PH9, Stainless steel pump is for PH1 to PH 14
3. Max grain diameter can be 60 percent of caliber for pump. Length of fiber can be 5 times as caliber for pump
4. Impurity weight into liquid can be not more than 15% of liquid weight. Liquid density is not more than 1240kg per cm3